Agilent announces the 8697 headspace sampler with integrated intelligence 15 mar 2021. Chemical analysis, life sciences, and diagnostics agilent. Agilent 34980a users guide agilent 34980a getting started guide agilent 34980a product reference cdrom. There is similarity between the instrument commands, however, the 34980a has evolved to use the most modern and widely accepted instrument command. Using the agilent 34980a with labview national instruments. Frontpanel number format when shipped from the factory, a period is used as the radix character and commas are used for the digits separator e. Agilent 34980a multifunction switchmeasure unit data sheet 8slot mainframe with 21 mixandmatch plugin modules so you can create your own custom configuration highperformance switching. A vertical bar separates multiple parameter choices for a given command string. Agilent 34980a multifunction switchmeasure unit data sheet 8slot mainframe with 19 mixandmatch plugin modules so you can create your own custom configuration highperformance switching. Keysight agilent 3498026503 backplane module price, specs. Refer to the 34980a service guide for specific information about these fuses. Software and drivers product documentation product data sheet application notes other product information lan. That doc applies to the 34980a mainframe and all available plugin modules.
Agilent technologies 75000 c series service manual service manual 56 pages agilent 117a operating and. Table 3 shows a summary of the programming control options available for the 3499abc and the 34980a. Please note that the use of these commands requires a detailed knowledge of the appropriate calibration procedures, which are described in the agilent 34980a service guide. For analysis in positive mode, the compounds were separated using acetonitrile mobile phase a and hplcgrade water with 0. Aug 03, 2014 the 34980a multifunction switchmeasure unit provides functionality that is easy to set up and use, with a fast startup time. Agilent technologies 34980a getting started manual getting started manual 28 pages. Agilent 34972a users manual innovative search service. Data logger for 34980a getting started guide 7 important. Keysight 53220a53230a 350 mhz universal frequency countertimer. Agilent technologies, incorporated manufacturers address.
Keysight 34980a is designed for indoor use in an installation category ii and low condensation environment. Keysight 34980a service guide 5 environmental conditions keysight 34980a is designed for indoor use in an installation category ii and low condensation environment. Keysight 53220a53230a users guide 5 lithium battery recycling the 53220a53230a counters contain a 3 v coin cell lithium battery. Agilent technologies 34980a getting started manual pdf. The menus are designed to automatically guide you through all parameters required to configure a particular function or operation. Front panel at a glance 2 rear panel at a glance 3 rear panel connector pinouts 4 external triggeralarms connector male dsub 4 analog bus connector female dsub 4 annunciator display indicators 5 front panel menu reference 6 instrument rack mounting 7. Instruments that appear damaged or defective should be made inoperative and secured against unintended operation until they can be repaired by qualified service personnel. See the agilent 34980a service guide for more information on returning the instrument to agilent for service. Keysight technologies 34980a multifunction switchmeasure unit. Agilent 34931a34933a matrix modules users guide 1 matrix modules this users guide covers the following three plugin modules for the agilent 34980a multifunction switchmeasure unit the 34931a has two dual matrices of latching armature switches. All three inputoutput interface connections come standard with the 34980a mainframe. Agilent 34980a multifunction switchmeasure unit programmers reference this help file contains reference information to help you program the agilent 34980a over the remote interface using the scpi programming language.
Do not use in locations where conductive dust or electrolytic salt dust may be present. When you use it with the internal dmm, you can configure each channel independently for the measurements you choose. If you choose to modify or upgrade your test system io, the 34980a is system ready. Agilent technologies agilent 34970a34972a data acquisition switch unit service guide page 1 thursday, december 10, 2009 7. Calibrate or troubleshoot the 34980a 34980a service guide. Up to 560 2wire multiplexer channels or 4096 matrix crosspoints in one mainframe optional builtin 6 1. This document contains references to agilent technologies.
To disconnect the mains from the instrument, remove the power cord. Page 4 the declaration of conformity doc for the 34980a mainframe instrument can be found on page iii in the 34980a mainframe users guide. Getting started, configuration, and programming information for the 34980a mainframe. Return the product to an agilent sales and service office for service and repair to ensure that safety features are maintained.
Module wiring information is located in the 34980a users guide. Calibration security this feature allows you to enter a security code to prevent accidental or unauthorized calibrations of the instrument. Agilent wins multiple 2020 scientists choice awards 10 mar 2021. Keysight recommends that this battery be replaced every year at the instruments 1year calibration interval. Rs232 communication with agilent 34970a ni community. Service manuals 34980a multifunction switchmeasure unit service manual includes information on specifications, troubleshooting and diagnostics, calibration procedures, rack mounting, obtaining service. Connecting the 34980a to your computer to easily connect the 34980a to your pc, configure and verify your connection, you can use the agilent io libraries suite. Agilent technologies 34970a manual manual 24 pages.
Up to 560 2wire multiplexer channels or 1024 matrix crosspoints in one mainframe optional builtin 6 1. Agilent 34980a multifunction switchmeasure unit mainframe users guide agilent technologies 1 introduction to the 34980a this chapter provides an overview of a computerbased data acquisition and measurement control system using the agilent 34980a multifunction switchmeasure unit. Agilent delivers complete scientific solutions, helping customers achieve superior outcomes in their labs, clinics, business and the world they seek to improve. Keysight technologies 34980a multifunction switchmeasure. If you use automated test equipment for design validation or manufacturing, you now have a costeffective solution for many test system applications. Show description getting started, configuration, and programming information for the 34980a mainframe. Keysight 34937a34939a users guide 9 general purpose switch modules this users guide covers the following two plugin modules for the keysight 34980a multifunction switchmeasure unit.
Agilent 34980a scpi programmers reference documentation. The 34937a provides independent control of 32 relays, including. Keysight agilent 34922t terminal block price, specs. Choose from 19 optional plugin modules that offer a broad range of functionality that includes dc to 20 ghz switching, countertotalizer, digital io with pattern capabilities, and da converters in one compact, highperformance modular platform. Separation was performed in an agilent tech nologies hplc series 1100, equipped with a reversedphase c18 analytical column zorbax sb, 250 mm 3. Verification and diagnostic tools for 34980a mainframe and modules select option for specific module support y12a. How your 3499abc test system benefits from upgrading to the new 34980a switchmeasurecontrol system.
View and download agilent technologies 34980a getting started manual online. Agilent technologies 34980a application note pdf download. Table below shows the general environmental conditions for this instrument. Please refer to that guide before attempting to calibrate the instrument as improper use of the calibration commands can adversely affect the accuracy and reliability of the instrument.
Agilent 34972a users manual innovative search service of. Genetic inactivation of cdk7 leads to cell cycle arrest. Please refer to that guide before attempting to calibrate the instrument as improper use of the calibration commands can. Agilent 34950a 64bit digital io and counter module users guide. This module also contains nine armature analog bus relays channels 911914. Agilent 34980a multifunction switchmeasure unit service guide. Keysight agilent 34921t terminal block price, specs. Keysight 34937a34939a general purpose switch modules. View and download agilent technologies 34980a application note online. Social media guide this article is meant to serve as a guide for scientists who would like to establish their online presence and includes an outline of the benefits of using social media as well as strategies for establishing and improving your presence in social media. Agilent 34980a multifunction switchmeasure unit mainframe users guide agilent technologies 1 introduction to the 34980a this chapter provides an overview of a computerbased data acquisition and measurement control system using the agilent 34980a multifunction switchmeasure unit and typical plugin modules. Calibration subsystem introduction 34980a documentation. Get proven performance from agilent instruments, with the resolution, repeatability, speed, and accuracy youve come to expect.
Agilent s former test and measurement business has become keysight technologies. Includes information on specifications, troubleshooting and diagnostics, calibration procedures, rack mounting, obtaining service, and much more. Agilent 34937a34939a general purpose switch modules users guide 1 general purpose switch modules this user s guide covers the following two plugin modules for the agilent 34980a multifunction switchmeasure unit. Agilent technologies 34950a user manual pdf download manualslib. See the agilent 34980a service guide for more information on returning the. Hpagilent 34980a multifunction switch measurement unit. A 34980a web interface provides a new easy way to communicate via lan with the instrument. Agilent 6500 series qtof lcms techniques and operation r1904a. Front panel at a glance 2 rear panel at a glance 3 rear panel connector pinouts 4 external trigger input connector male dsub 4.
Twentyeight form c relays, each rated for 1 a at 60 w per channel. Agilent technologies 34980a user manual pdf download manualslib. Sales and service office for service and repair to. Agilent 34980a multifunction switchmeasure unit challenge the. For a more detailed discussion of the calibration procedures, see the agilent 34980a service guide. Sw loveland, co 80537 usa declares under sole responsibility that the product as originally delivered. Agilent technologies 34980a user manual pdf download. The calibration commands are used to calibrate the agilent 34980a. Guide for information on supported external reference sensors. Aug 28, 2020 the agilent 34980a is a good instrumentation solution for manual bench top testing or multiple automated test equipment use cases.
This kit includes rack mount brackets and associated hardware required to forward or reverse mount the instrument in the rack cabinet. Replacement procedures are provided in the 53220a53230a service guide. Page 1 agilent 34980a multifunction switchmeasure unit users guide agilent. The 34980a offers builtin signal conditioning and modular flexibility. Third edition may 2012 the tolerances used by this procedure were taken from the published. Choose from 21 optional plugin modules that offer a broad range of functionality that includes dc to 26. Includes y1a rack mount the agilent 34980a is an eightslot mainframe that includes an optional builtin 6 a. Agilent technologies 34970a service manual service manual 273. Table of contents syntax conventions measurement commands temperature configuration commands voltage configuration commands resistance. Agilent 34980a multifunction switchmeasure unit command quick reference version 1. Keysight agilent 34921a 40channel armature multiplexer. The 34980a helps you lower your cost of test and accelerate your testsystem integration and development. Read the safety, warning and caution information in the 34980a users guide before operating or connecting wiring to the 34980a and its modules.
Up to 560 2wire multiplexer channels or 4096 matrix crosspoints in. This cdrom is located on the inside back cover of the 34980a users guide and contains. Agilent 34980a multifunction switchmeasure unit data sheet challenge the boundaries of test agilent modular products. Rackmount kit for 34980a, forward or reverse mount order e3663ac rail kit for forward rack mounting or e3664ac rail kit for reverse rack mounting y11a. This command specifies the value of the known calibration signal as outlined in the calibration procedures in the agilent 34980a service guide. Up to 560 2wire multiplexer channels or 1024 matrix crosspoints in. For more information, go to this help file contains reference information to help you program the keysight 34970a34972a over a remote interface using the programming language. The keysight 34922a module for the 34980a multifunction switchmeasure unit offers high density multiplexer switching in a compact size. Agilent technologies agilent 34980a multifunction switchmeasure unit users guide test equipment depot 800. That doc applies to the 34980a mainframe and all available plug in modules. Preset when shipped from the factory, a period is used as the radix character and commas are used for the digits separator e. The 34980a supports the scpi command language on all of its remote io interfaces. This command is used for internal dmm calibrations. It combines dense, multifunction switching with 100 channelsecond scan rates to address a broad spectrum of data acquisition applications.